TECHNICAL GUIDE AND QUANTITY REPORT

Knauf W112: double-layer partition

W112.es combines a single frame with two Knauf boards on each side. Its build-ups can increase acoustic, mechanical and fire performance.

Calculate materials for W112
This guide and quantity report support product selection and ordering. They do not replace project design, professional approval or checks for loads, fixings, junctions and site-specific conditions.
Variants
3
Thickness range
98–120 mm
Documented EI
EI 60 / EI 120
Documented Rw
54–57 dB

DECISION SHEET

When to choose W112

Best suited to

The balanced W11 option: two boards per side to add mass, robustness and performance without moving to a three-layer wall.

Compare first with

W112 adds one layer per side over W111; W113 is the alternative where a heavier three-layer build-up is required.

Critical site checks

  • For fire-rated variants, use 250 mm screw spacing and fully treat the joints in every layer.
  • Do not claim certified fire resistance for walls boarded horizontally.
  • Keep the documented board, stud width, layer count and screw specification together as one build-up.

Available W112 variants

Choose a specific build-up to open the quantity report with that system already loaded. Only performance values published by the associated technical source are displayed.

Build-upThicknessBoardsFrameFireAcousticMax. heightCalculate this variant
W112 · 98 mm2 × boards per face 98 mm 2 × Knauf Standard A board 12,5 Knauf stud and channel 48 EI 60 Rw 54 dB 3.1 m Calculate this variant
W112 · 120 mm2 × boards per face 120 mm 2 × Knauf Standard A board 12,5 Knauf stud and channel 70 EI 60 Rw 55 dB 4 m Calculate this variant
W112 · 120 mm2 × boards per face 120 mm 2 × Knauf Diamant board 12,5 Knauf stud and channel 70 EI 120 Rw 57 dB 5 m Calculate this variant

How to choose a W112 variant

Selection depends on stud width and board type. The documented Diamant build-up provides higher performance than the loaded Standard variants when installed as a complete system.

The Ferragut quantity report prepares

  • Boards on both faces
  • Compatible studs and channels
  • Cavity insulation
  • Screws for every layer
  • Tape, compound and acoustic seal
Calculate materials for W112

What this system family contains

The composition comes from the loaded variants and identifies the work items involved before preparing the quantity report.

012 × Knauf Standard A board 12,5
02Knauf stud and channel 48
03Knauf Insulation mineral wool
04Knauf stud and channel 70
052 × Knauf Diamant board 12,5

Questions about Knauf W112

What is the Knauf W112 system?

W112.es combines a single frame with two Knauf boards on each side. Its build-ups can increase acoustic, mechanical and fire performance.

Which W112 variant should I choose?

Selection depends on stud width and board type. The documented Diamant build-up provides higher performance than the loaded Standard variants when installed as a complete system.

What does the calculator quantify?

The tool estimates complete purchase units for boards, profiles, insulation, screws, joint treatment and accessories compatible with the selected build-up.

Where does the technical data come from?

Performance data comes from W11.es Tabiques Knauf con estructura metálica (2026), revision 2026-07. Values that are not published are not inferred.

FAMILY COMPARISONCompare W111, W112 and W113Compare build-ups →